PCLTA-20 PCI Interface User's Guide 3-7
Priority: the priority application output buffer count, as calculated by the
driver based on information retrieved from the PCLTA-20 card’s non-volatile
EEPROM.
Loaded Image Size: the size, in bytes, of the currently-loaded PCLTA-20 system
image. This may be zero if the PCLTA-20 card is in the initial boot state.
Interrupt Count: the number of interrupts the driver has processed for this
device. This value is set to zero when the device is physically reset.
Diagnostic Commands
The diagnostic commands are invoked by clicking one of the buttons displayed in figure
3.6. If a diagnostic command results in the “Image file not found” error message, close
the Diagnostics dialog by clicking the OK button, then click the Apply button in the
PCLTA-20 control panel application. This re-initializes the card and allows use of the
diagnostic commands.
Figure 3.6 Diagnostics Dialog Box Commands
Test
The Test button retrieves status and error counts from the PCLTA-20 card. The
results of this message will be displayed in the format shown in figure 3.7.