I/O Model Reference 53
Figure 18. Muxbus I/O for Series 3100 Devices and Timing
Table 20. Muxbus I/O Latency Values for Series 3100 Devices
Symbol Description Minimum Typical Maximum
t
fout
io_out() call to valid address — 26.4 μs —
t
as
Address valid to address strobe — 10.8 μs —
t
ahw
Address hold for write — 4.8 μs —
t
ahr
Address hold for read — 6.6 μs —
t
was
Address strobe width — 6.6 μs —
t
wrs
Read strobe width — 10.8 μs —
t
wws
Write strobe width — 10.8 μs —
t
dws
Data valid to write strobe — 6.6 μs —
t
rset
Read setup time 10.8 μs — —
t
whold
Write hold time 4.2 μs — —
t
rhold
Read hold time 0 μs — —
t
adrs
Address disable to read strobe — 7.2 μs —
Comentarios a estos manuales